CLAMP ON SENSOR 9272-05

Ideal for Measuring AC Current with Low Frequencies
such as Inverter Control Devices

Hioki current sensors are best-in-class devices for use with power
meters, Memory HiCorders and high performance oscilloscopes. The
9272-10/9272-05 are a 1Hz to 100 kHz AC current sensor ideal for
measuring low frequency equipment such as inverters.

Model No. (Order Code)

9272-1020/200 A AC, PL23 terminal
9272-0520/200 A AC, ME15W terminal
CE
 

Note: This product cannot be used alone.
The optional Sensor Unit is required in order
to supply power and connect the clamp to a
Memory HiCorder or other instrument.
The clamp can be directly connected to a
compatible Power Meter, or Power Analyzers.

CAT III 600 V
Key Features

• Superior low frequency and phase characteristics suitable for testing the current and power of inverter control devices
• Wide 1 Hz to 100 kHz frequency bandwidth perfect for harmonic analysis, FFT analysis and waveform monitoring (AC only)

Basic specifications (Accuracy guaranteed for 6 months, Post-adjustment accuracy guaranteed for 6 months)

Rated current20 A AC, or 200 A AC (selectable)
Max. allowable input50 A rms (at 20 A range), 300 A rms (at 200 A range)
Frequency characteristics1 Hz (±2 % rdg. ±0.1 % f.s.) to 100 kHz (±30 % rdg. ±0.1 % f.s.)
Amplitude and Phase accuracyAmplitude: ±0.3 % rdg. ±0.01 % f.s. Phase: ±0.2 ° (45 to 66 Hz)
Output voltage2 V/20 A rated current range, or 2 V/200 A rated current range
(voltage output with the Sensor Unit, use with a device having a 1 MΩ input resistance or higher)
Max. rated voltage to earth600 V rms (CAT III)
Core diameterφ 46 mm (1.81 in)
Power supply±11 V to ±15 V DC (Power suppled via the Sensor Unit, which supports 100 to 240 V AC)
Power consumption5 VA Max. (when measuring 200 A)
Dimensions and mass78 mm (3.07 in) W × 188 mm (7.40 in) H × 35 mm (1.38 in) D, 430 g (15.2 oz), cord length: 3 m (9.84 ft)
AccessoriesCarrying case 9355 ×1, Instruction manual ×1, Mark bands ×6

Compatible models...9272-10 (-05)

Compatible models9272-109272-05
Power Analyzer PW3390△ (Requires CT9900)OK
Power Analyzer 3390OK△ (Requires CT9901)
Power HiTester 3193 seriesOK△ (Requires CT9901)
Current Unit 8971△ (Requires the 9318)△ (Requires the 9318, CT9901)
F/V Unit 8940△ (Requires the 9318, 9705)△ (Requires the 9318, 9705, CT9901)
Catalog: AC/DC CURRENT SENSOR CT6860 seriesDownload PDF  [2MB]English
Catalog: SENSOR UNIT CT9555, CT9556, CT9557Download PDF  [1MB]English
Catalog: HIGH ACCURACY/ WIDEBAND CURRENT SENSOR SeriesDownload PDF  [5MB]English

For more information, click here

-->