Prevent Chances of Downtimes To Increase Productivity and Profitability.
According to a research in 2011, every minute downtime in a data center will result in a loss of approximate $5,600 USD. The research also highlighted that more than 39 percent of the downtime was due to data center’s power, which consists of UPS system failure (including batteries) and generator failure.
Therefore, regular predictive and preventive maintenance of data centers is crucial, so as to maximise the performance and reliability of mission-critical equipment, which can prevent chances of downtimes, and thus increase productivity and profitability. Hioki provides measurement solutions for the maintenance of Data Centers highly sensitive equipments. Here, we will introduce measuring instruments for each section:
1. Substations
2. Power Control Boards
3. Switchboards
4. UPS
5. In-house Generators
6. PV Systems
7. Grounding Rods
8. Air-conditioning
9. 5G Antennas
10. Data Servers
Verify Phase Rotation
Test Insulation
Test Supply Voltage
Verify Load Current
Detect Leakage Current
Detect Electrical Disturbances. Analyze Power Quality
Record and Analyze Electrical Consumption
Test 5kV Insulation
Equipment Damage and Malfunction Due To Power Quality
Record Sudden Problems
Missed By The SNMP*
Clarify Trouble Spots via Simultaneous
Recording of 3 Systems
*SNMP : Simple Network Management Protocol – A protocol use to monitor the live and operational status of IP devices, widely use for measuring rack temperature and current.
Implement Reliable Maintenance Programs With
Efficient Measurement Data Management
Detect Electrical Disturbances. Analyze Power Quality
Reliable Preventive Maintenance of UPS
Diagnose Deterioration Of Lead-Acid Batteries
(also measure lithium-ion batteries)
Measure Mixed AC and DC signals
Measure correctly even in noisy environments.
Address inverter noise emitting from UPS
Reach deep with battery racks.
L2020 test lead with L-shaped tip
Thin jaw tackles complicated wire with ease.
AC/DC Clamp Meter CM4376
Verify Phase Rotation
Verify Motor Insulation
Test Supply Voltage
Test Load Current
Test Bypass Diodes
Verify Grounding
Test PV Insulation
Verify String Current
Verify String Current
Verify Grounding
Verify Phase Rotation
Test Supply Voltage
Test Load Current
Check Voltage, Temperature and Humidity
Check Temperature and Humidity
Check Temperature
Verify LAN Wiring